Darmowa wycena

Szybki kontakt

Anti-corrosion protection gantry crane

A comprehensive renovation of corrosion protection crane with the development of technology.

Mountaineering renovation Steel Construction crane for PCC Rokita SA with the development of technology renovation.

Works include:

  • Sandblasting the degree of structure Sa 2.5 according to ISO 8501,
  • Development Technologies Security corrosion in a corrosive environment C5-I Long for durability (above 15 years),
  • Implementation of Security corrosion in the system czterowarstwowym to a thickness of 360 microns total,

Technical data: 

  • Total Construction completion date: 2300 m2,
  • Painting System: epoxy – polyurethane
  • The total thickness of the coating 360 microns,
  • Duration: 35 DAYS
  • Corrosive environment: C5-I

Client: PCC Rokita SA
PLACE implementation: Brzeg Dolny POLAND

7 November 2016

Other accomplishments

Security R15 fire protection

Washing elevation M1 Shopping Center

Climbing Washing elevation CH Ursynow

Washing elevation CH STER

A comprehensive renovation of the roof

A comprehensive Kindergarten’s roof renovation

See all accomplishment